ASTM D3330 EPUB

31 Jan ASTM D describes six methods used to test the adhesion strength of pressure sensitive tape. Learn how to test pressure sensitive adhesive tapes to ASTM D with the best equipment. “These test methods are under the jurisdiction of ASTM Committee D on. Packaging published as D – 76 Last previous cdition D/DM –

Author: Malabei Maukinos
Country: Ukraine
Language: English (Spanish)
Genre: Science
Published (Last): 27 November 2008
Pages: 29
PDF File Size: 2.20 Mb
ePub File Size: 8.83 Mb
ISBN: 883-1-59606-755-7
Downloads: 44347
Price: Free* [*Free Regsitration Required]
Uploader: Doshura

It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. The area under stress varies astm d3330 backing stiffness and adhesive rheology astm d3330.

In a face-side application, the tape is adhered to a standard steel panel or your astm d3330 substrate in the same manner as the previous methods mention with pressure sensitive tape.

The assessment may be within a roll of tape, between rolls, or between production lots.

Astm d3330 you would rather see the data in real-time and study the peel interface at the same time, we would provide you with asrm XyLive Software. When testing liner side adhesion, the face side adhesive is adhered to a thin polyester film.

Pressure asttm tape is used in a variety of applications including duct astm d3330, electrical tape, masking tape, astm d3330, double-sided tape, bandages, medical devices, and other uses.

Although we can provide you with guidance, we recommend you purchase and closely follow the ASTM International testing standard.

ASTM D3330 Tape Adhesion Strength Testing

Rated to N 50 lbf Maximum specimen thickness of 8 mm 0. Referenced Documents purchase separately The documents listed below are astm d3330 within the subject standard but are not provided as part astm d3330 the standard. Repeat steps of Test Method A. Apply a second strip of the tape to the backing of the first strip on the test panel, taking care to align the edges of the second specimen with those of the strip in the test panel.

TOP 10 Related  UNDERSTANDING CHESS TACTICS BY MARTIN WETESCHNIK PDF DOWNLOAD

Adhere another specimen on top of the one on the plate and run the test. Test Methods A, B, C, E or F cannot be used to compare astm d3330 pressure-sensitive tapes of the same type but of different manufacture for their ability to adhere to a surface.

Remove a mm specimen of the tape to astm d3330 tested. Link to Active This link will always route to the current Active version of the astm d3330.

In a liner-side application, the transfer tape is applied to a strip of 0.

astm d3330 If the adherent is set on an angle, that will cause an error. ASTM D includes six astm d3330 methods for testing the peel adhesion strength of pressure sensitive tape. These test methods are tools for quality assurance use. These test methods may not provide design information as there is usually no direct relationship between asgm adhesion and any functional requirement. Have a question about conducting the test for this standard?

When testing face side adhesion, the double-coated tape is adhered to a stainless astm d3330 panel or your chosen substrateliner side up.

ASTM D Peel Adhesion Pressure Sensitive Adhesive Tapes

Substitution of representative samples of materials in question for the astm d3330 steel panel would suffice to do this.

The purpose of ASTM D data results help assess the uniformity of adhesion for pressure sensitive tapes. Sales Support Calibration Calculators. Forces up to 10 kN 2, lbf Low force tabletop systems Modular astm d3330 of five frame options with adjustable test space Affordable testing option for tension, compression, bend, peel and much more.

TOP 10 Related  STK412-150 PDF

D Astm d3330 of Packaging and Distribution Environments. ASTM D is one astm d3330 the more popular r3330 standards to determine the adhesive strength of pressure sensitive tapes.

Fold back the tab to a 90 degree angle and connect it to the grip.

The P consists of a vertical load frame, an electromechanical actuator, load cell, a tocuhpad test controller, XY test software and peel grips. The plate is placed horizontally into the test machine and the free end of the tape is grasped in the machine grips.

This plot will be an important aspect of data retrieval and astm d3330 we highly recommend our XyPlot software. Therefore, these test methods cannot be used to pinpoint the specific cause s of astm d3330. We offer machines, apparatus, testers, tensile grips, test fixtures, clamps, holders, jigs, faces, jaws, astm d3330, environmental and humidity chambers, furnaces, baths and custom solutions for unique applications.

The force will be different at other peel rates. Place the panel into the peel test machine grips and peel back 22 mm of the astm d3330 half of the tape sample so that the specimen is doubled over astm d3330 at degrees.